Bis monitor for sedation in icu pdf

Fletcher, in pediatric critical care fourth edition, 2011. Patients admitted to intensive care and on mechanical ventilation, are. Other measuring systems require further development and validation to be useful in the icu. Use of bispectral index to monitor the depth of sedation. Over and undersedation of patients is a widely recognized challenge in icus, where sedation assessment has been guided primarily by vital signs or subjective sedation assessment scales. Ramsay sedation 5 scale and richmond agitation sedation scale raas 6. Monitoring critically ill, braininjured patients with a decreased level of consciousness is challenging. Bis monitoring is an easy to use adjunct to monitoring sedation in the critically ill patient, that may reduce costs, morbidity, and mortality related to sedation in the icu ellie z. Early bispectral index and sedation requirements during. Bispectral index bis monitoring litfl ccc neurology. Sedation is the depression of a patients awareness to the environment and reduction of his or her responsiveness to external stimulation. In the control arm, the sedation assessment tools for ca included the sedation.

Bis monitors evidence and practice student doctor network. The bispectral index bis, a processed variable derived from the raw electroencephalogram eeg used to guide sedation in the intensive care unit icu, has not been tested during barbiturate. Anxiolysis relief of apprehension or agitation with minimal alteration of sensorium. Mechanical ventilation barbiturate coma bedside procedures neuromuscular blockade the bis monitoring system is most useful. Bis monitoring versus clinical assessment for sedation in. During out of office hours and weekends, ceeg monitoring is not always available.

Muscle activity may interfere with reliable bis monitoring performance. Although many promising objective methods measuring systems are available, there are no truly validated instruments for monitoring intensive care unit icu sedation. Overestimation of bispectral index in sedated intensive care. Doses up to 200 gkgmin have been used in the icu setting. The bis monitor reports a single number from 0 to 100 that represents an integrated measure of. A computer search of englishlanguage articles in medline 1966july 2005. Pdf role of the bispectral index in sedation monitoring in the icu.

Using a specialized bedside electroencephalographic monitor, clinicians can achieve individualized levels of moderate sedation analgesia with predictive targeted brain wave values. The bis monitor thus gives the anesthetist an indication of how deep under anesthesia the patient is. The electromyogram responsiveness is not sufficiently sensitive to monitor sedation in icu patients 7. Bis monitoring and reduced risk of awareness in adults sedation critical care a tool for objective assessment of sedation in the icu until now, sedation assessment has been primarily guided by vital signs or subjective sedation assessment scales. Sedation assessment in a mobile intensive care unit.

Bis monitoring may not consistently measure patient sedation or decrease awareness during anesthesia. Assessing bis monitoring in critical care 20030401 ahc. The icu patient may have a limited number of ways to express themselves and a patient who is pulling at monitoring lines may be distressed, in pain, delirious or a. Instruments for monitoring intensive care unit sedation. The lack of a gold standard for measurement of sedation makes the evaluation of sedation in critically ill patients difficult. Olson says his hospital began bis monitoring about four years ago as part of a research protocol for anesthesiologists. In icu, bis monitors are used in different contexts when patients have intracranial hypertension bis and sr values are used to titrate barbiturate treatment 10, 11. This does not replace train of four tof monitoring. S88s98 november 2018 with 885 reads how we measure reads. Bis technology enables medical professionals to reliably gauge the precise amount of anesthetic medication required by each patient, resulting in better overall patient care.

The bispectral index is a statistically based, empirically derived complex parameter. Bispectral index bis provides an objective measure of sedation. Bispectral index monitoring basics article nursingcenter. Preceded, opioids, ketamine, will not effect your bis value but will act synergistically and increase sedation. A sensor on the patients forehead translates brain electrical activity into a single bis value, ranging from 0 to 100. Bispectral index to monitor propofol sedation in trauma patients. Sedation, analgesia, and paralysis in the intensive care unit. Early diagnosis of nonconvulsive status epilepticus. Several studies using different target bis ranges have reported the use of bis monitoring to augment sedation in icu patients. Postoperatively, patients were screened for delirium via the camicu. Revisiting bispectral index monitors in the medical icu.

Pdf the assessment of sedation level in critically ill patient remains a. Icu sedation 2009 2 about this document the purpose of this document is to provide intensive care settings with recommendations and tools for the development and implementation of an evidencebased standard for safe and effective management of pain, sedation, and delirium in adult intensive care unit icu ventilated patients. Correlation of bispectral index and richmond agitation. Sedation for patients in icu intensive care society. Bispectral index monitoring an overview sciencedirect. The main objective of the present study was to assess the agreement of bis with. Bispectral index monitoring of icu patients on continuous infusions of paralytics and sedatives reduces sedative drug cost as well as the recall phenomenon. Available guidelines discourage use as primary monitor in nonparalyzed critically ill patients. The depth of sedation is calculated by measuring cerebral electric activity via an electroencephalogram eeg. Significant undersedation may occur using subjective analysis of sedation in the icu. A bispectral index bis monitor is commonly utilized to assess depth of sedation when administering sedative, hypnotic, or anesthetic agents during surgical and medical procedures. Overestimation of bispectral index in sedated intensive. Use of bispectral index to monitor the depth of sedation in. Applegate rl 2nd, lenart j, malkin m, meineke mn, qoshlli s, neumann m, jacobson jp, kruger a, ching j, hassanian m, um m.

The bis is an empirical, statistically derived measurement. Comparing bis monitoring with clinical assessment for. Bispectral index bis technology was the first clinically proven and commercially available direct measure of the effects of anesthetics and sedatives on the brain. Analgosedation is a cornerstone therapy for mechanically ventilated patients in intensive care units icu. The aim of this study was to investigate whether monitoring of analgosedative drug concentrations midazolam and sufentanil might be beneficial to optimize analgosedation and whether. Significant under sedation may occur using subjective analysis of sedation in the icu. Franges, 2009 numerous studies have documented the ability of bis to reduce intermediate outcomes such as. A bis value between 40 and 60 indicates an appropriate level for general anesthesia, as recommended by the manufacturer. Using bispectral index monitoring to gauge depth of. For several years, the bispectral index bis, a variable derived from the electroencephalogram, has been reported as a quantifiable measure of the depth of sedation and degree of awareness during and after general anesthesia 1,2 and of the depth of sedation in the intensive care unit icu.

Bis monitor aspect and sedline hospira monitor have been proposed as a means of nearcontinuous assessment of patient level of sedation. Further, close monitoring promotes repeated evaluation of. Given the limitations of rass to monitor sedation level, a new method was required. It is a weighted sum of several electroencephalographic subparameters, including a time domain, frequency domain, and high order spectral subparameters. Bispectral index bis monitoring of icu patients on continuous infusions of sedatives and paralytics reduces sedative drug utilization. Bispectral index monitoring correlates with sedation scales. Assessing bis monitoring in critical care 20030401. The trial found that the duration of mechanical ventilation and icu stay were significantly shorter in the group that underwent daily interruption of sedation 2. Patients receiving therapeutic paralysis may experience inadequate sedation due to intrinsic limitations of behavioral sedation assessment.

Those poorquality data points were registered as artefacts in our study protocol. Bis monitor was used to assess the level of sedation in the intervention arm in all the studies. A bis sedation level between 4560 will be maintained, for deeper sedation on patients requiring aggressive ventilatory management or if specifically ordered by a physician. Neuromuscular blockade the bis monitoring system is most useful for patients who are chemically paralyzed andor moderately to deeply sedated. Pdf role of the bispectral index in sedation monitoring. In the control arm, the sedation assessment tools for ca included the sedationagitation scale sas, ramsay sedation scale rss or subjective ca utilizing traditional clinical signs heart rate, blood pressure, conscious level and pupillary size. Sedation will not be discontinued on any patient with neuromuscular blockade based solely on bis monitor readings. Evaluating and monitoring analgesia and sedation in the. Role of sedation and analgesia in icu article pdf available in anaesthesia, pain and intensive care 22suppl 1. The current study has several limitations, most related to the protocol used for administering sedatives, administering neuromuscular antagonists, and monitoring sedation during therapeutic hypothermia. Tof monitoring should still be completed to determine the degree of nmb. Should not be used in patients with a history with an allergy to eggs.

A computer search of englishlanguage articles in medline 1966july 2005, international pharmaceutical abstracts 1971july 2005, and scientific citation index expanded 1980july 2005 was conducted. But unlike in the operating room, where measurement of endtidal anesthetic gas concentration is used to gauge sedation, no such monitors exist in the icu. Bis sedation target range of 4560, unless specifically ordered by physician. Overall, bis monitoring is an easytouse adjunct to monitoring sedation in the critically ill patient that may reduce costs, morbidity, and mortality related to sedation in the icu. Monitoring of sedation depth in intensive care unit by therapeutic. Auditory evoked potentials can be used only for research in patients with a deep level of sedation. This study looks to assess whether monitoring sedation status in mechanicallyventilated medical surgical intensive care unit msicu patients using bispectral index bis monitoraugmented sedation monitoring as opposed to richmond agitation sedation scale rass score is associated with decreased duration of mechanical ventilation.

However, supportive evidence in application of bis during ffb are still lacking. Sedative agents there is a wide choice of sedative medications which can be used to achieve the desired level of sedation. Applying bis to monitor the depth of anesthesia had been widely accepted and gained popularity. Other researchers found that the correlation between sedation scores and bis was suboptimal and inconsistent in the heterogeneous icu population. The essence of bis is to take a complex signal the eeg, analyse it, and process the result into a single number. Chris is an intensivist and ecmo specialist at the alfred icu in melbourne. Within some limits, it appears reliable for measuring the depth of sedation in the intensive care unit icu,68 although large ranges of bis values at various predefined sedation levels are commonly observed in icu patients. Bis data were excluded from sedation assessment if the bis monitor electromyography index was 50% andor if the signal quality index fell short of 75%. In one study, titration of sedation with bis monitoring in icu patients. Sedation is used almost universally in the care of critically ill patients, especially in those who require mechanical ventilatory support or other lifesaving invasive procedures.

Bispectral index bis monitoring amanda chadwell summer. Called the bispectral index bis monitor, this noninvasive device can be used without assistance from highly specialized clinicians. He is also the innovation lead for the australian centre for health innovation at alfred health, a clinical adjunct associate professor at monash university, and the chair of the australian and new zealand intensive care society anzics education committee he is a cofounder of the australia and new zealand. A randomized evaluation of bispectral indexaugmented. These approaches may not be sufficient to achieve optimal patient assessment. Algorithm for monitoring of sedation, delirium, and pain in adult patients. The use of bis monitoring to assess for recall in anesthetised patients in the operating theatre room for short periods of time is quite different to its use in monitoring critically unwell patients who may be receiving continuous sedation and analgesia in the icu for prolonged periods of time. There is a significantly different bis value between each sedation score p nov 24, 2014 for sedation assessment, all paramedics were trained in obtaining the rass and bis measures.

Apr 01, 2003 over and under sedation of patients is a widely recognized challenge in icus, where sedation assessment has been guided primarily by vital signs or subjective sedation assessment scales. In ramsay sedation scale, scales 1 to 3 constitute awake states and scales 4 to 6 constitute asleep levels. Reducing the risk of postoperative delirium via bispectral. Adverse effects include hypotension, bradycardia and myocardial depression. Role of the bispectral index in sedation monitoring in the icu. Assessing sedation during intensive care unit mechanical ventilation with the bispectral index and.

We hypothesised that the bispectral index of the eeg bis could be a helpful tool in evaluating the depth of sedation in this difficult environment. The bis monitor provides a calculated dimensionless numeric variable between 0 deep sedation with isoelectric eeg and 100 patient fully awake. For sedation assessment, all paramedics were trained in obtaining the rass and bis measures. The bis monitor reports a single number from 0 to 100 that represents an integrated measure of cerebral electrical activity. The bispectral index bis monitor was developed to assess the hypnotic component of general anesthesia johansen, 2006. The bispectral index bis monitor can be used to assess the hypnotic component of general anesthesia. Available guidelines discourage use as primary monitor in non. The relationship between the bis value and moass score during sedation. Management of analgesia and sedation in the intensive care unit. Several researches have reported that bis values are significantly correlated with rass scores for evaluating sedation in icu patients 16. The bis monitor provides a single dimensionless number, which ranges from 0 equivalent to eeg silence to 100.

Bispectral index can reliably detect deep sedation in. Box plots represent 2575th percentile, whisker bars represent the 5th and 95th percentiles. Appropriate treatment of generalized convulsive refractory status epilepticus rse requires general anesthesia in the intensive care unit icu with continuous electroencephalography ceeg monitoring. The bis monitor provides a direct measure of the effects of sedatives on the brain. Sedation is commonly used in icu and sedation protocols are in widespread use and are considered best practice. To avoid inadequate sedation and its complications, monitoring of analgosedation is of great importance. Apr 17, 2019 low bis associated with increasing delirium this can increase morbidity and mortality currently no high level evidence to guide use in icu possible role for patients who are paralysed in the titration of adequate amounts of sedation and analgesia. The bispectral index bis is a processed electroencephalogram eeg monitor that measures the hypnotic effects of anesthetics and sedatives. Icu, sedation, critically ill patients, deep sedation, agitation, benzodiazepines a johns hopkinsled study on sedation practices in critically ill patients in a resourcelimited setting finds that deep sedation, agitation, and benzodiazepines were independently associated with worse clinical outcomes. Monitoring of sedation depth in intensive care unit by. Philips bispectral index bis measurement uses aspect medical systems xp platform technology. Sedation in icu patients need for standardised protocols. Bispectral index bis monitoring standard of practice icu.

Agitation scale sas, ramsay sedation scale rss or subjective ca utilizing traditional clinical signs heart rate, blood pressure, conscious level and pupillary size. Can bis monitoring be used to assess the depth of propofol. Mar 30, 2019 sedation is the depression of a patients awareness to the environment and reduction of his or her responsiveness to external stimulation. The aim of this study was to investigate whether monitoring of analgosedative drug concentrations midazolam and sufentanil might be beneficial to optimize analgosedation and. The bis value is a numerical value ranging from 0 to 100 and represents a signal processed electroencephalographic eeg value derived from proprietary software 19. There is a significantly different bis value between each sedation score p sedline brain function monitoring. It provides depth of consciousness and sedation monitoring for use in the or, icu, and other clinical settings. In the critical care setting, the bis monitor is commonly used to allow objective assessment of sedation during. In the control arm, the sedation assessment tools for ca included the sedation agitation scale sas, ramsay sedation scale rss or subjective ca utilizing traditional clinical signs heart rate, blood pressure, conscious level and pupillary size. In the control group the infusions were interrupted only at the discretion of the clinicians in the icu.

The bispectral index bis monitor is one of the most commonly used objective monitor of sedation depth in ventilated intensive care unit patients on neuromuscular blockade. The bis represents a method of monitoring that can be an important adjunct to clinical assessment and other monitoring modalities used in the icu setting. Often when we put a bis on a sick icu patient the value will be 40 without any anesthesia, whatever that. Advanced monitoring is associated with fewer alarm events during planned moderate procedurerelated sedation. May 19, 2017 applying bis to monitor the depth of anesthesia had been widely accepted and gained popularity. Bispectral index to monitor propofol sedation in trauma. Background sedative drug administration is a challenging aspect of the management of mechanically ventilated patients in the outofhospital critical care medicine. Our goal is to determine in this population the correlation between the bispectral index bis and three commonly used sedation agitation scales.